High Dynamic Professional Power Amplifier

The HD2000 is a Class H amplifier with 1000 + 1000 W @ Stereo 4Ω power output in a 19’’/2U format, ideal for use in fixed installations.
HD2000 incorporates the soft-start circuit with gradual volume increase, clip limiters and special protection features such as temperature control, overcurrent, DC output and anti-short circuit on the outputs.
The whole HD series is based on our proven High Dynamic Power technology, which means higher efficiency in the ratio of power output versus energy consumed.

 

 

Voltage Gain

32 dB

Input Sensitivity

1.74 V

Input Impedance

20 kΩ

Slew Rate

+/-12 V/μs

Output Power (1 kHz – 0,1% THD) (1)

  • Stereo 8 Ω /  600 + 600 W
  • Stereo 4 Ω / 1000 + 1000 W
  • Stereo 2 Ω / 1500 + 1500 W (2)
  • Bridge 8 Ω / 2000 W
  • Bridge 4 Ω / 3000 W (2)

Average Current draw (1/3 power) (3)

5 A @ 230 V AC

Frequency Response

20 Hz – 20 kHz (0/-1 dB)

Damping Factor (1 kHz @ 8 Ω)

350

Crosstalk

65 dB

S/N Ratio (A-weighted)

105 dB (A)

Mains

220 – 240 V AC- 50/60 Hz

Dimensions (HxWxD)

88 x 482 x 440 mm

Weight

18 kg

  • (1) Continuous burst tone 20 ms (0 dB) / 480 ms (-20 dB) in accordance with EIA RS-490 and IEC 60268-3(IHF A-202).
  • (2) Driving the amplifier at 2 Ω channel / 4 Ω bridge at full power mode in poor ventilation conditions may cause a thermal overload protection. 2 Ω power is time limited by mains circuit breaker.
  • (3) Heavy duty musical program
Specifications
Voltage Gain

32 dB

Input Sensitivity

1.74 V

Input Impedance

20 kΩ

Slew Rate

+/-12 V/μs

Output Power (1 kHz – 0,1% THD) (1)

  • Stereo 8 Ω /  600 + 600 W
  • Stereo 4 Ω / 1000 + 1000 W
  • Stereo 2 Ω / 1500 + 1500 W (2)
  • Bridge 8 Ω / 2000 W
  • Bridge 4 Ω / 3000 W (2)

Average Current draw (1/3 power) (3)

5 A @ 230 V AC

Frequency Response

20 Hz – 20 kHz (0/-1 dB)

Damping Factor (1 kHz @ 8 Ω)

350

Crosstalk

65 dB

S/N Ratio (A-weighted)

105 dB (A)

Mains

220 – 240 V AC- 50/60 Hz

Dimensions (HxWxD)

88 x 482 x 440 mm

Weight

18 kg

  • (1) Continuous burst tone 20 ms (0 dB) / 480 ms (-20 dB) in accordance with EIA RS-490 and IEC 60268-3(IHF A-202).
  • (2) Driving the amplifier at 2 Ω channel / 4 Ω bridge at full power mode in poor ventilation conditions may cause a thermal overload protection. 2 Ω power is time limited by mains circuit breaker.
  • (3) Heavy duty musical program

 